What Size Air Conditioner For 1000 Square Feet

Need Help Sizing Your Equipment? Click Here

Easy To Use A/C Size Selection Tool: Check the colour coded map above and confirm the zone your home is in. Then, on the chart included underneath, select the square footage of your abode forth with the zone you're in. From there you lot can select ane of units that will be about efficient for your dwelling.

ZONE 1 ZONE 2 ZONE 3 ZONE four ZONE v
1.five Tons 600 - 900 sf 600 - 950 sf 600 - 1000 sf 700 - 1050 sf 700 - 1100 sf
2 Tons 901 - 1200 sf 951 - 1250 sf 1001 - 1300 sf 1051 - 1350 sf 1101 - 1400 sf
2.five Tons 1201 - 1500 sf 1251 - 1550 sf 1301 - 1600 sf 1351 - 1600 sf 1401 - 1650 sf
3 Tons 1501 - 1800 sf 1501 - 1850 sf 1601 - 1900 sf 1601 - 2000 sf 1651 - 2100 sf
3.five Tons 1801 - 2100 sf 1851 - 2150 sf 1901 - 2200 sf 2001 - 2250 sf 2101 - 2300 sf
4 Tons 2101 - 2400 sf 2151 - 2500 sf 2201 - 2600 sf 2251 - 2700 sf 2301 - 2700 sf
5 Tons 2401 - 3000 sf 2501 - 3100 sf 2601 - 3200 sf 2751 - 3300 sf 2701 - 3300 sf

Proper System Sizing

A lot of real science is included in the methods of calculation when selecting the correct size key air conditioner for your domicile. For case, i of these methods is a Residential Load Calculation.

Another method for sizing air conditioners is determining the size of the air conditioner organisation that's currently in place. Manufacturers normally don't listing the size of the air conditioner unit but don't worry! The system capacity is almost e'er coded into the model number of the outdoor unit.

In about cases you tin use the conversion information below to help in determining the size of your existing air conditioner organisation (use the system model number Non the series number)

18 = 1.5 tons
24 = 2 tons
30 = 2.5 tons
36 = three tons
42 = iii.5 tons
48 = 4 tons
60 = 5 tons

A Warning Before Y'all First Sizing Your Air Conditioner: Practise non to make the error of buying an A/C that's also large! When yous install an air conditioner that'south besides large for the infinite, it does what is called a 'short cycle'. A short wheel is when the compressor doesn't run for enough time to dehumidify the surface area you're trying to climate control. A short cycling A/C system isn't the only concern; in most cases the system volition cycle on and off more often, this translates to an increase in operating costs and an overall reduction in the system'south life. Proper air conditioner sizing is critical to optimize performance.

Heating Square Footage By Climate Zone

ZONE 1 ZONE two ZONE three ZONE 4 ZONE five
thirty - 35 Btu's per square pes 35 - 40 Btu'southward per square human foot 40 - 45 Btu'southward per square pes 45 - 50 Btu'south per foursquare foot l - threescore Btu'southward per square human foot

Heating Guide

Hither nosotros will cover how to apply the heating guide portion of this selection guide. You will need to utilise the lower of the two numbers if you know your home to be well insulated; apply the higher number if your home is older and poorly insulated – be honest! It volition pay off in the stop. (Hither'southward another Hint: You should select the larger of the two numbers if you're completely unsure of your dwelling house's insulation)

If you lot can notice your furnace model number, you can skip the calculation and look up your model number to find exactly what you need. Please refer to this furnace model number decoder to aid determine what you lot currently accept. If you have issues with this, give us a call and nosotros are happy to help.

Yous will then rapidly multiply the correct number higher up past your home's total heated square footage. At this signal you will take arrived at your judge heating capacity requirement.

An example y'all tin reference: If your abode is in the yellow zone, your dwelling house is adequately insulated, and you've got 2000 heated square feet, the equation will look something similar this:

2000 square feet
X 40 heating factor (from the chart above)
80,000 Btu actual output

Adjacent, if yous demand to calculate the output yous need on a gas furnace, just multiply its efficiency by its listed input rating for the BTU output of estrus.

An example you can reference: If a furnace is listed with an input rating of 100,000 BTU's and an efficiency rating of 80%, it would produce:

100,000 Btu input
X .80 efficiency
lxxx,000 Btu actual output

If the aforementioned 100,000 BTU furnace has an efficiency rating of 93% it will produce:

100,000 Btu input
Ten .93 efficiency
93,000 Btu bodily output

Seeing a pattern here? In the example above, using an eighty% efficient furnace, the 2000 square foot habitation above would crave a 100,000 BTU input furnace which will produce the necessary 80,000 BTU's output of heat.

Variables

Let's talk about all of the variables that come into play when selecting a new air conditioner system or furnace. One such Variable is your insulation, some other whole fix of variables being the type and number of windows in the space, number of stories in your home, the construction type, etc. All of these variables will greatly bear on the required BTU's per foursquare for both heating and cooling. A skillful dominion to follow is if your home is well insulated and has newer style windows, y'all can (in most cases) safely choose the smaller size arrangement that conforms to the specs needed for your total square footage.

Is your home 2 story? If the reply to that question is 'yes' it volition place less of a load on the system in the downstairs flooring because the 2d floor acts as boosted insulation. If your home isn't well insulated or if information technology has older manner windows and an obscenely high number of windows, you're going to want to select a larger system that falls inside your specified square footage range. The less insulated and more windows inside the environment, the more than likely you will experience greater air and heat loss.

Click hither for a Manual J calculation for your home

Quick Sizing

Sizing Calculator

Commercial Packaged Unit of measurement Ac Sizing

In this section we will assistance y'all to determine the correct size for your commercial organization. It is always recommended to go with the aforementioned size equipment that you take currently however this guide will assistance you size for new construction or addons.

The first step is to calculate the foursquare footage of your building or the rooms you are wanting to absurd. Please notation that the following calculations are based off of an 8' ceiling.

Once y'all have the square footage, divide that number by 500.

Side by side you volition want to multiply the number by 12,000. This volition give you the base BTU's required to absurd the area.

We recommend to add together 380 for each person that works in that space throughout the day. We also recommend to add i,000 for each window and 1,200 for each kitchen.

Once y'all take the all of the items added up you will desire to split up by 12,000. This will requite you the required tonnage to absurd your commercial space.

Duct Work Sizing

Duct work sizing is too very critical when upgrading or changing your system. Nosotros have come up upward with a simple guide to size your duct work. Please go along in mind that this guide is only to be used as an estimate and we would highly recommend a technician to cheque your duct piece of work and ensure that the proper duct piece of work size is used. Click hither to see the duct work sizing chart.

What Size Air Conditioner For 1000 Square Feet,

Source: https://hvacdirect.com/sizing-air-conditioner-and-heater.html